About MINIATURE DRY BLOCK TEMPERATURE CALIBRATOR
Model: TCAL 1404/-15
Display: 2.8" True TFT with Touch screen
Temperature Range: -15 to 120C
Radial uniformity: (Better than) 0.03C
Resolution: 0.01 C
Stability: 0.03 C
Temperature readout: C
Heating time:
Amb to 120-->25min
-15 to Amb -->5 min
Cooling time:
Amb to -15 -->20min,
120 to 50-->8 min
Stabilization time: 10 mins
Well Dimension(dia. x height): 20 x 90 mm
Well immersion depth: 90 mm (throw hole)
Standard well holes in mm: 6.2 x 2nos
Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz
Power consumption: 100 w
Overall Dimension in mm: 170 x 95 x 183 mm
Instrument Weight: 3.5 Kg
Compact Yet Powerful Calibration SolutionThis miniature calibrator offers impressive capabilities in a highly compact footprint, making it convenient for both laboratory and on-site calibration needs. Its robust stainless steel block and multi-hole insert mean you can calibrate multiple types of sensors without needing several devices. The digital LED display and PID controller provide precise temperature control, ensuring your readings are both accurate and consistent.
Fast Performance and Easy OperationWith a rapid heating time-reaching maximum temperature in just 12 minutes-this calibrator is designed for efficiency. Simply insert your sensor into the removable insert, set the desired temperature using the user-friendly controls, and benefit from stable calibration conditions. The device operates on standard 230V AC, 50 Hz mains, making it easy to set up anywhere.
Safe and Reliable for Diverse ApplicationsSafety is paramount, which is why an over-temperature cut-off feature is included to protect both the instrument and your sensors. This calibrator excels in routine maintenance, testing, and verification in industries and labs, ensuring your temperature measurement equipment meets quality and regulatory requirements.
FAQ's of MINIATURE DRY BLOCK TEMPERATURE CALIBRATOR:
Q: How do I use the miniature dry block temperature calibrator for calibrating sensors?
A: To use the calibrator, insert your temperature sensor into the appropriately sized hole of the removable block insert. Power on the device, set the desired temperature using the digital controls, and wait for the block to stabilize (typically within 12 minutes). Once stable, measure your sensor's reading against the displayed value for calibration.
Q: What types of sensors can I calibrate with this instrument?
A: This calibrator is suitable for RTDs, thermocouples, thermistors, and various temperature probes, thanks to its multi-hole insert accommodating different sensor diameters.
Q: When should I perform calibration using a dry block temperature calibrator?
A: Calibration should be conducted periodically, according to your facility's quality policies, after significant sensor use, or whenever a sensor's accuracy is in doubt to ensure precise temperature measurement and compliance with standards.
Q: Where can this calibrator be used effectively?
A: Due to its compact and lightweight design, the calibrator is suitable for laboratories, industrial sites, and field environments-anywhere precise sensor calibration is required.
Q: What is the process for changing the insert to accommodate different sensor sizes?
A: The insert is removable and can be easily swapped with another block featuring different bore sizes. Simply allow the device to cool, remove the existing insert, and replace it with the desired one for your sensor type.
Q: What are the benefits of using this calibrator over other methods?
A: This calibrator provides a fast, stable, and accurate temperature environment, ensuring high-quality calibration with minimal setup and reduced risk of contamination compared to liquid baths. The digital controls and safety features enhance both efficiency and instrument protection.